b'Building Code OscarscontinuedCITY OF fire sprinklers. with significant improvements, BURIEN The average size of a Normandyor structures relocated to WUI 509 Park guest house permittedareas. The focus is on exterior between 2018 and 2023 wasfire-resistant materials. WUI code-726 s.f. The average cost of acompliant examples: permitted fire service sprinklerMetal or Mason-set roofssystem for R-3 construction fromExterior construction materials 2021 to 2024 YTD was $7,453. rated for not less than 1-hour Under the new residential code,fire-resistance. altered, added to, or movedRoof flashing materials not less structures will now need tothan 0.019 inches.PUGET SOUND comply with the InternationalMultilayered glazed panels/Existing Building Code, ratherwindows for fire protection than being updated to therated for no less than 20 min.current adopted code. A regional roofing company noted an average range of asphalt ALRARKOEW Category: Best Coderoofing of $11,000 to $27,000, while Update in Adapted Homesmetal roof average costs range Wildland Urban Interface in a Protective Role from $27,500 to $67,500. Costs can WeUgIe -t aIntetde rUmnixinhabitedVCity Limit Ns umber of afected parcels 488Parcels |dDyensity MF (Min. 5,000 sf) be factored in differently through W-a5t eLrobwo R 00 sf) The ICC and SBCC are adopting R-7.2 High Density SF ( MSiFn .( M7,i2n0. 01 2s,f5)R-12.5 Medium Density ,000 s 0f0)sf) initial material costs, installation R-15 Lowd iuDmen DiumSiFtyn Min (. M 1in5.( 1 280 ,0nits/acre) Wildland-Urban Interface (WUI) RM sietyn sDe (M uRM- 0 Me0HMiegdh Density MF (24 units/acre)R-2-12 800 siFty MF Parks 40 enter (NC) labor, maintenance, and other N CITY OF building codes as a new code entry Meixigedh bUosrheo (oMdU C) DES MOINES this cycle (yes, its pronouncedconstruction work.Woo-Ee.). Parts of NormandyCategory:Park fall under the wildland-urbanOther Nomineesintermix*, a low-degree risk for 0 500 1,000 2,000 3,000 4,00F0eet properties in those areas.Other ICC-SBCC code updates of CITY OF NORMANDY PARKWUI codes will only apply tonote for Normandy Park customers:WILDLAND URBAN INTERFACE new developments, structuresCodes now require that kitchen hoods meet a certain threshold of CFM exhaust depending on the type of fuel, electrical or natural gas:Electrical kitchen hood: 160 CFMCombustible kitchen hood: 250 CFMIf King County Public Health requires radon reduction systems, a test result at or below 4 pCi/L must be achieved. Mitigation and retesting must occur until the standard is met.The SBCC adopted a less proscriptive version of the Residential Energy Compliance Table compared to 2018, due to trade-offs for heat pump requirements. 12 Normandy Park City SceneSpring 2024'